FLIR A310 pt thermal cameras can be installed almost anywhere to monitor the condition of your critical equipment and other valuable assets. Designed to help safeguard your plant and measure temperature differences, they allow you to see problems before they become costly failures — preventing downtime and enhancing worker safety. FLIR A310 pt is ideal for various applications that require temperature measurement capabilities including: substation, transformer, waste bunker, and coal pile monitoring.

Specifications
Ethernet Video Streaming
Two independent channels for each camera – MPEG-4, H.264, or M-JPEG
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Effective Pixels
380.0
f-number
1.3
Image Frequency
30Hz
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
Accuracy
±4°C (±7.2°F) or ±4% of reading
Alarm Functions
6 automatic alarms on any selected measurement function, camera temperature
Communication & Data Storage
Ethernet
Control, result and image
Ethernet Communication
TBA
Ethernet Connector Type
RJ-45
Ethernet Protocols
Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
100 Mbps
Ethernet Video Streaming
Two independent channels for each camera – MPEG-4, H.264, or M-JPEG
Video Out
Composite video output, PAL /NTSC compatible
Imaging & Optical
Array format
320 × 240
Azimuth Range
Az velocity 360° continuous, 0.1 to 60°/sec max
Color Palettes
Color palettes (BW, BW inv, Iron, Rain)
Detector Pitch
25 µm
Detector Time Constant
Typical 12 ms
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
Effective Pixels
380.0
Electronic Zoom
12× continuous, digital, interpolating
Field of view – visual
57.8° (H) to 1.7° (H)
Field of view (FOV)
15° × 11.25°
FLIR Screen-EST Mode
No
f-number
1.3
f-number – visual
1.6 to 4.5
Focal Length
30.38 mm (1.2 in.)
focal length – visual
3.4 mm (wide) to 122.4 mm (tele)
Focal Plane Array (FPA)
1/4″ Exview HAD CCD
Focus
Automatic or manual (built in motor)
focus – visual
Automatic or manual (built in motor)
Image Frequency
30Hz
IR Resolution
320 × 240 pixels
Lens Identification
Automatic
Minimum Focus Distance
1.2 m (3.93 ft.)
Optical Zoom
36× continuous
Spatial resolution (IFOV)
0.82 mrad
Spectral Range
7.5–13 µm
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
Video Standard
CVBS (ITU-R-BT.470 PAL), CVBS (SMPTE 170M NTSC)
Zoom
1–8× continuous, digital, interpolating zooming on images
Measurement & Analysis
Accuracy
±4°C (±7.2°F) or ±4% of reading
Alarm Functions
6 automatic alarms on any selected measurement function, camera temperature
Area
10 boxes with max./min./average/position
Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Emissivity Correction
Variable from 0.01 to 1.0
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Isotherm
1 with above/below/interval
Measurement Corrections
Global and individual object parameters
Object Temperature Range
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Programmable Presets
128.0
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
Set-up Commands
Date/time, Temperature°C/°F
Spot Meter
10.0
General
Automatic Heater
Clears window from ice. Switched on at +4°C (39°F). Switched off at +15°C (59°F).
Housing material
Aluminum
List of Contents
Cardboard box, Pan & tilt with infrared camera including lens, and visual camera, FLIR Sensors Manager download card, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Packaging Size
671 x 564 x 464 mm (26.4 x 22.2 x 18.3 in.)
Size [L × W × H]
460 × 467 × 326 mm (18.1 × 18.4 × 12.8 in.)
Weight
17.8 kg (39.3 lb.)
Environmental & Certifications
Bump
5 g, 11 ms (IEC 60068-2-27)
Elevation Range
El velocity ± 45°, 0.1 to 30°/sec. max
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Encapsulation
IP 66 (IEC 60529)
Humidity (Operating and Storage)
IEC 60068-2-30/24 h 95% relative humidity +25° C to +40°C (+77°F to +104°F)
Operating Temperature Range
–25°C to +50°C (-13°F to +122°F)
Storage Temperature Range
–40°C to +70°C (–40°F to +158°F)
Vibration
2 g (IEC 60068-2-6)
Power
Power
24 VAC (21-30 VAC; 24 VAC: 215 VA max. with heater) or 24 VDC (21-30 VDC; 24 VDC: 195 W max. with heater).