MDR-10-12: 10W Single Output Industrial DIN Rail Power Supply, 12V, 85~264VAC In, 12VDC/10W Out , – 20 ℃ ~ 70 ℃, 3 Year Warranty, Supports: AW-IHS-0200,AW-IHS-0201,AW-IHS-0203
Technical Specification
OUTPUT
DC VOLTAGE: 12V
RATED CURRENT: 0.84A
CURRENT RANGE :0 ~ 0.84A
RATED POWER: 10W
RIPPLE & NOISE (max.) Note.2: 120mVp-p
VOLTAGE TOLERANCE Note.3: ±3.0%
LINE REGULATION: ±1.0%
LOAD REGULATION: ±3.0%
SETUP, RISE TIME Note.5: 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.): 120ms/230VAC 25ms/115VAC at full load
INPUT
VOLTAGE RANGE: 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE: 47 ~ 63Hz
EFFICIENCY (Typ.): 81%
AC CURRENT (Typ.): 0.33A/115VAC 0.21A/230VAC
INRUSH CURRENT (Typ.): COLD START 35A/115VAC 70A/230VAC
LEAKAGE CURRENT: <1mA / 240VAC
PROTECTION
OVERLOAD:
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE:
13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
DC OK ACTIVE SIGNAL (max.): 9 ~ 13.5V / 40mA
ENVIRONMENT
WORKING TEMP.: -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY: 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/℃ (0 ~ 50℃)
VIBRATION: Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
SAFETY STANDARDS: UL508, TUV EN60950-1 approved
WITHSTAND VOLTAGE: I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
EMC IMMUNITY: Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
OTHERS
MTBF: 584K hrs min. MIL-HDBK-217F (25℃)
DIMENSION: 22.5*90*100mm (W*H*D)
PACKING: 0.17Kg; 72pcs/13.2Kg/0.91CUFT
NOTE
1. All parameters NOT Specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12†twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI†testing of component power supplies.â€
5. Length of set up time is measured at cold first start. Turning ON/OFF power supply may lead to increase to the set up time.